Industrial air heaters are designed to heat large working areas, structures and equipment effectively and economically with forced air heat in extreme cold conditions. The Dragon Fire Hot Air Unit can also be used in conjunction with other heating systems. Hot air units are mobile and provide an independent heating source for spot heating equipment. Units can be skid or trailer mounted and have dual fuel capability (oil/natural gas) with sizes ranging from 1.4 Mbtu/hr - 5 Mbtu/hr.

Literature

Download the
Dragon Fire Hot Air Unit Brochure

Downloadable Dragon Fire Hot Air Unit Brochure
Download PDF
Dragon Fire Specifications
Unit Size 1.4MBTU 2.2MBTU 3.0MBTU
Heat 1,400,000 BTU/HR, Indirect Fired 2,200,000 BTU/HR, Indirect Fired 3,000,000 BTU/HR, Indirect Fired
Controls Honeywell & Thermologic Honeywell & Thermologic Honeywell & Thermologic  
Blower 7,000 CFM @ 4" Static Pressure 9,000 CFM @ 4" Static Pressure 11,000 CFM @ 4" Static Pressure  
Blower Motor 10 Hp. TEFC motor,1760 RPM 10 Hp. TEFC motor,1750 RPM 15 Hp. TEFC motor, 1760 RPM  
Electrical 240V 3Phase 60Hz 480V 3Phase 60Hz 480V 3Phase 60Hz  
Air Outlet One 20” x 20" Air Duct One 24" x 24” Air Duct One 24" x 24” Air Duct  
Burner C1-O Power FlameHi Lo Operation C2-GO-15 Power Flame Ul Full Modulating C2-GO-20B Power Flame Ul Full Modulating  
Fuels #1 & #2 Diesel, Natural Gas #1 & #2 Diesel, Natural Gas #1 & #2 Diesel, Natural Gas  
Fuel Capacity 196 gal. Diesel Tank 196 gal. Diesel Tank 196 gal. Diesel Tank  
Fuel Rate 9.7 GPH max 15.7 GPH max 22.0 GPH max  
Gas Rate 1400 MBH max 2200 MBH max 3080 MBH max  
Temp. Rise 200° F 200° F 200° F  
Construction All Major Components USA mfg. All Major Components USA mfg. All Major Components USA mfg.  
Heat Exchanger 2 Pass Stainless Steel Tube 2 Pass Stainless Steel Tube 2 Pass Stainless Steel Tube  
Dimension 23.2’ L x 7’-11” W x 8’-6” H 32.0’ L x 8’- 4” W x 8’-10” H 32.0’ L x 8’- 4” W x 8’-10” H  
Weight Approx. 12,000 lbs. Approx. 17,500 lbs. Approx. 19,000 lbs.  
     
Unit Size 4.2MBTU 5.0MBTU
Heat 4,200,000 BTU/HR,Indirect Fired 5,000,000 BTU/HR,Indirect Fired
Controls Honeywell & Thermologic Honeywell & Thermologic    
Blower 21,000 CFM @ 4” Static Pressure 24,000 CFM @ 4” Static Pressure    
Blower Motor 30 Hp. TEFC motor, 1725 RPM 50 Hp. TEFC motor, 1725 RPM    
Electrical 480V 3Phase 60Hz 480V 3Phase 60Hz    
Air Outlet One 36” x 36” Air Duct One 36” x 36” Air Duct    
Burner C3-GO-20 Power Flame UL Full Modulating C3-GO-25B Power Flame UL Full Modulating    
Fuels #1 & #2 Diesel, Natural Gas #1 & #2 Diesel, Natural Gas    
Fuel Capacity 196 gal. Diesel Tank 196 gal. Diesel Tank    
Fuel Rate 30.0 GPH max 37.5 GPH max    
Gas Rate 4200 MBH max 5250 MBH max    
Temp. Rise 200° F 200° F    
Construction All Major Components USA mfg. All Major Components USA mfg.    
Heat Exchanger 2 Pass Stainless Steel Tube 2 Pass Stainless Steel Tube    
Dimension 32.0’ L x 8’-4” W x 8’-10” H 35.8’ L x 8’-4” W x 10' H    
Weight Approx. 20,000 lbs. Approx. 24,000 lbs.